BWC4-B-N BW Clip4 4-Gas Detector (O2, LEL, H2S, CO), North American version - Black Housing
Details
Details
"Always on" technology with Honeywell safety and dependability
When you're fully occupied on the job, the last thing you need is hassles with your gas protection system. Why worry about charging the gas detector, checking the battery, or replacing sensors when you don't have to? The BW Clip4 is designed for simplicity, ease of use, and cost-effective ownership. It's one less thing to worry about. As you go through your busy day, you receive constant protection from Honeywell's supporting technology and quality.
Runs Continuously for Two Full Years
It's as easy as activating and clipping it on. Never charge it up or think about the battery for 24 months.
FEATURES
Wearing the BW Clip4
Comfortable, ergonomic, and durable
Small profile - in tight spaces, it's unnoticeable
Using BW Clip4
Single-button operation
User-friendly and virtually tamper-proof operation
Intuitive LCD icon technology shows you real-time gas readings
BW Clip4 Compliance
Non-compliance indicators let you know the unit hasn't been bump tested on schedule
Battery, sensors, circuit integrity, and visual/audible alarms are automatically tested daily
BW Clip4 Management
IntelliDoX docking simplifies data management
BW Clip4 Durability
The boot is concussion-proof
Tested under harsh conditions
BW Clip4 Technical Specifications
TYPICAL BATTERY LIFE Two years, continuous operation
EVENT LOGGING 70 of your most recent events
OPERATING TEMPERATURE -20 to +50°C (-4 to +131°F)
HUMIDITY 5 - 95% RH (non-condensing) continuous
SIZE 4.7 x 2.7 x 1.3 in. / 12.0 x 6.8 x 3.2 cm
WEIGHT 8.2 oz. / 233 grams
INGRESS PROTECTION rated at IP68
ALARMS Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, OL (over limit)
SELF-TEST: Activated detectors automatically perform one internal diagnostic test every24 hours (sensors, battery, and circuitry).
BW Clip4 Options
Set STEL for 1-minute intervals (from 5 to 15 minutes)
Calibration span levels
Calibration interval setting
Bump test interval setting
Stealth mode
Select combustible gases measurement: 0-100% LEL (Lower Explosive Limit) or Methane gas 0-5.0% v/v
Calibration due date from 1 to 365 days (or zero for off)
Individual sensor control
Latching alarms
APPROVALS AND CERTIFICATIONS:
Class I, Div 1, Group A, B, C, D
Class I, Zone 0, Group IIC
ATEX: II 1G Ex ia IIC T4 Ga
IECEx: Ex ia IIC T4 Ga
X: Conforms to all (applicable) European directives.
For additional certifications, please refer to the manual or contact Honeywell Analytics.
WARRANTY Full two years (includes battery & sensors)